● IP65 IP69K - Waterproof, Dustproof, Moisture-proof and Vapour proof
● Clear and Frosted diffuser available
● PC and PMMA diffuser available ( PC-IK10 , PMMA-Anti-Ammonia )
● Aluminum heat sink inside, better for heat dissipation
● Can be Surface Mounted or Suspended
● With Merrytek brand sensor- Microwave motion & Daylight sensor
● CE, RoHS, SAA & C-tick approved
● Sensor & Emergency versions available
● Flicker free available
● Dimming available
● The sensor is plug type, you could pull out the sensor when you don't need it
Applications:
| ● Coal plants | ● Power plants | ● Animal farms |
| ● Tunnels | ● Overpass | ● Car Parks |
| ● Food processing plants | ● Flower farms |
Specification
Video
Contact

Technical Specifications

Packing information

| Specification for Microwave Motion Sensor MC085S A (Needle Connector) ● Detection area, hold time and daylight sensor can be set by DIP switch. ● Two modes optional: Photocell function and Motion function. ● Quick switch ON/OFF 3 times to override sensor function. Lights will switch on all the time. |
Parameter
Sensor Parameters | Operating Frequency | 5.8 GHz ±75 Mhz,,ISM Band. |
Transmitting power | 0.5mW Max. | |
Hold time | 5S/30S/90S/3min/20min/30min | |
Detection | 25%/50%/75%/100% | |
Daylight Sensor | 2Lux/10Lux/25Lux/50Lux/100Lux / Disable | |
Daylight open/close | 10Lux/50Lux ; 25Lux/75Lux; 50Lux/100Lux; 100Lux/200Lux; 150Lux/300Lux; Disable | |
Mounting Height | Suggested: 2.5-4m, 6m max | |
Detection Area | 4-6m (Radius), Mounting height 3m | |
Detection Angle | 150° (Wall mounting), 360° (Ceiling mounting) | |
| Operating | Operating Temperature | -25℃+60℃ |
Function

Detection Area (Sensitivity)
| 1 | 2 | ||
| Ⅰ | ON | ON | 100% |
| Ⅱ | - | ON | 75% |
| Ⅲ | ON | - | 50% |
| Ⅳ | - | - | 25% |
Hold time
| 3 | 4 | 5 | ||
| Ⅰ | ON | ON | ON | 5s |
| Ⅱ | - | ON | ON | 30s |
| Ⅲ | ON | - | ON | 1min |
| Ⅳ | - | - | ON | 3min |
| Ⅴ | ON | ON | - | 20min |
| VI | - | - | - | 30min |
Daylight Threshold
| 6 | 7 | 8 | ||
| Ⅰ | ON | ON | ON | 2Lux |
| Ⅱ | - | ON | ON | 10Lux |
| Ⅲ | ON | - | ON | 25Lux |
| Ⅳ | - | - | ON | 50Lux |
| Ⅴ | ON | ON | - | 100Lux |
| VI | - | - | - | Disable* |
*Disable means the daylight sensor does not work.
The sensor will turn on light once motion is detected regardless of ambient light level.
Photocell
| 6 | 7 | 8 | Open/Close | |
| Ⅰ | ON | ON | ON | 10Lux/50Lux |
| Ⅱ | - | ON | ON | 25Lux/75Lux |
| Ⅲ | ON | - | ON | 50Lux/100Lux |
| Ⅳ | - | - | ON | 100Lux/200Lux |
| Ⅴ | ON | ON | - | 150Lux/300Lux |
| VI | - | - | - | Disable* |
*Disable means the daylight sensor does not work.
The sensor will turn on light once motion is detected regardless of ambient light level.
Mode Settings
| 9 | Mode Settings | |
| Ⅰ | ON | Motion |
| Ⅱ | - | Photocell |



Please Note:
* Product must be installed by licensed electrician.
* Disconnect or turn off the power before installation.
* Verify the supply Voltage is the same as rated luminaire voltage.
Packing List (each inner box):
* Tri-proof light: 1pcs
* Screw: 4pcs
* Brackets: 2pcs
* Sensor: 1pcs
X