STORM AU01 LED Tri-Proof Light - Emergency


image.png


● IP65 - Waterproof, Dustproof, Moisture-proof

● Full PCB board and the diffuser is a whole part, no need to take the PCB apart but wire directly, much easier than the normal design

● Cables can be from the back or the two ends of the light, easy wiring

● Easy end clips, one step assembly

● With Safety cables, free your hands during the installation

● Can be Surface Mounted or Suspended

● Can be linked one to another

● CE, RoHS, SAA & C-tick approved 

● LiFePO4 Battery adopted, 3.5W run 3 hours

● 3 years warranty for whole lamp

● Single CCT & Tri-color available 

● Flicker free ,Triac Dimming, 1-10V Dimming & Dali Dimming available


Applications:

  ● Parking lots● Warehouses● Factories
  ● Tunnels● Basements● Lofts
  ● Balcony● Car washing station


Specification Video Contact

Product Dimention

image.png


Technical Specifications

image.png


Packing information

image.png


Wiring Diagream

image.png


Testing

When luminaire is permanently connected to mains supply, allow the luminaire to fully charge for 16 hours.

Conduct following tests once the battery has fully charged:


Test 1:

A commissioning discharge test must be carried out once the luminaire is connected to mains supply.

The emergency luminaire must remain illuminated for at least 2 hours after disconnection from the mains power.

NOTE: The luminaire works on standard power when connected to mains supply and switches to 3.5W power during. 

emergency mode operation.


Test 2:

Subsequent tests, performed every 6 months, require the luminaire to successfully operate in emergency mode for 90mins. 

NOTE: A record shall be maintained of all the discharge tests performed on site at all times.


Test Switch and LED Indicator:

The Test Switch and LED indicator on the luminaire provide an indication of the status of the luminaire during

testing and normal operation

image.png


Install Instruction


image.png

image.png


Please Note:

* Product must be installed by licensed electrician.

* Disconnect or turn off the power before installation.

* Verify the supply Voltage is the same as rated luminaire voltage.


Packing List (each inner box)

Tri-proof light: 1pcs

Screw: 6pcs

Brackets: 2pcs

Connector: 1pcs

Clip used to hold the wires 1pcs